CabFab Collective Protection

CabFab Shelter Fabrics
Chemical and Biological Protection for Military Tents and Shelters

CabFab's Shelter fabrics are specially designed to provide provides impermeable chem/bio protection for military applications. Developed in coordination with the Natick Soldier Center, CabFab meets the needs for military protection from chemical and biological agent attacks at an affordable weight and cost. CabFab will provide collective protection against all chemical and biological agents including HD, GD, and VX agents.

CabFab meets all requirements of the Joint Expeditionary Collective Protection (JECP). Tents and shelters may be designed completely with the CabFab coated fabrics and still provide the necessary agent protection. The use of CabFab in shelter design eliminates the need for protective liners, reducing overall system weight, costs, and setup time. A shelter incorporating the CabFab fabric will provide significant more flexibility than stiff Teflon coated Kevlar while providing the same levels of chemical agent protection.

CabFab will meet all the physical property requirements of LP/P DES 1-94B Limited Production Purchased Description for Cloth, Chemical and Biological Protective. The fabric will also meet the requirements of Mil-PRF-44103. The coated fabric is compatible with all current manufacturing technologies and requires no special equipment to use. Seaming of the fabric can be done either by RF or heat sealing using one of our adhesive tapes. No stitching is required.

The tent material is available in colors of green/white, green/green, tan/white, and tan/tan. CabFab is available in widths up to 63 inches.

Typical Properties

Property Units Test Method Value
Weight oz/yd2 ASTM D7736 13 -14
Break Strength, Warp psi ASTM D751 >320
Break Strength, Fill psi ASTM D751 > 320
Tear Strength lbs ASTM D4851 75
Hydrostatic Resistance psi ASTM D751 >300
Water Absorpotion % Fed-STD-191
Method 5502
>1.9
Flame Resistance sec. Fed-STD-191
Method 5905
<0.5
Abrasion Resistance g Fed-STD-191
Method 5306
<0.01
Blocking Fed-STD-191
Method 5872
>None
HD Resistance micro-g/cm2 CRDC-SP-84010 <0.75
tGD Resistance micro-g/cm2 CRDC-SP-84010 <0.10
VX Resistance micro-g/cm2 CRDC-SP-84010 <0.04